Silicone high temperature resistant coating

Apr 17, 2020

Silicone high temperature resistant paint is formulated with silicone resin, heat resistant pigments, additives, solvents, etc. The product has rapid surface drying, good adhesion, good flexibility, (single) two-component packaging and easy construction. Features of non-stick coatings such as high temperature resistance.
characteristic
The paint is a high-performance, high-temperature resistant coating, and the coating has good sealing properties after film formation. The product can (depending on color) withstand high temperatures of 250-800 ℃.
use
It is suitable for all high-temperature resistant environments and protects it from high-temperature corrosive media. Such as engine casing, chimney, exhaust pipe, heat exchanger, etc.
Construction storage
(1): The surface of the object must be cleaned of dust, oil, welding slag, rust, and old paint film before painting. The steel surface should be sandblasted and shot blasted to Sa2.5 level, and the local repair surface should be polished to St3 level. . Moisture is strictly prohibited during construction.
(2): The single component of this material can be mixed evenly before construction. The proportion of the two-component paint is: component A: component B = 14.2kg (large barrel): 4.3kg (small barrel). The proportioning method of the two-component construction is: fully open the first part of the component A, add the component B to the component A, and mix well. It can be painted.
(3): The paint quality is too thick and can be diluted with special thinner. Unfinished materials should be sealed and stored.
(4): When the rainy day or relative humidity is greater than 75%, the construction should be stopped.
(5): The product should be stored in a cool and dry place, to prevent direct sunlight, isolate the source of fire, and away from heat.
(6): The storage period is twelve months. After the period expires, all technical indicators should be inspected. If the index requirements are met, they can continue to be used.